Identification & traceability of exhaust particulate filters


Customer need
- A complete marking & reading workstation directly integrated in the particulate filter cleaning process
- Receive data from the PLC
- Mark a unique identifier on each part: 24 alphanumeric characters + 2D Data Matrix™ code
- Verify the mark before validating the cycle
- Communicate the information to a traceability network (BUS) to store the data
Requirements
- 2 workstations integrated into initial and final identification cycle
- Cycle time: 15 seconds
- Production: 250 parts per day
- Material: stainless steel of various surface conditions (possible oxidation & modification caused by thermal shocks)
Technifor's solution
- Marking: Technifor XF510m electromagnetic Micro-Percussion machine with M1C - 90° stylus
- Reading: 3 Cognex Insight 1010 cameras
- High intensity fluorescent ring light
End-user benefits
Technifor supplied a complete & customized solution, meeting all customer requirements.
This solution provides the manufacturer an automated traceability guarantee for parts throughout the part life cycle from production to the final customer.