Customer need

  • A complete marking & reading workstation directly integrated in the particulate filter cleaning process
  • Receive data from the PLC
  • Mark a unique identifier on each part: 24 alphanumeric characters + 2D Data Matrix™ code
  • Verify the mark before validating the cycle
  • Communicate the information to a traceability network (BUS) to store the data

Requirements

  • 2 workstations integrated into initial and final identification cycle
  • Cycle time: 15 seconds
  • Production: 250 parts per day
  • Material: stainless steel of various surface conditions (possible oxidation & modification caused by thermal shocks)

Technifor's solution

  • Marking: Technifor XF510m electromagnetic Micro-Percussion machine with M1C - 90° stylus
  • Reading: 3 Cognex Insight 1010 cameras
  • High intensity fluorescent ring light


End-user benefits

Technifor supplied a complete & customized solution, meeting all customer requirements.